Uses
Conplast MS micro silica is primarily used to improve the
properties of hardened concrete where a reduction in
permeability, increased durability and resistance to chlorides,
sulphates, abrasion, frost attack and alkali silica reaction are
required.
Advantages
Significantly reduces permeability by minimising the
penetration of moisture and aggressive elements
Significant reduction in chloride ion penetration by reducing
continuous capillary pores
Improved mechanical properties
Description
Conplast MS supplied as a fine powder is added to the
concrete mix early during the mixing process. The resultant
low permeability concrete will exhibit improved mechanical
properties, and increased resistance to the effects of
chlorides, sulphates, gases, frost attack and alkali silica
reaction.
Technical Support
Fosroc provides a technical advisory service for on-site
assistance and advice on admixture selection, evaluation
trials and dispensing equipment. Technical data and
guidance can be provided for admixtures and other products
for use with fresh and hardened concrete.
Standards compliance
Conforms to ASTM C1240-95a.
Dosage
Typically 4 to 10% by weight of cement depending upon the
specific need. The optimum dosage of Conplast MS to meet
specific requirements should always be determined by trials
using the materials and conditions that will be experienced
in use.
Please note higher addition levels are generally required
where the high performance concrete such as high strength
concrete or underwater concrete is a pre-requisite.
Properties
Chemical analysis
SiO2 Min. 85%
Alkalies as Na2
O Max. 1%
Loss on ignition Max.5%
Bulk density Approx. 610 kg/m3
Application instructions
Dispensing and mixing
Conplast MS should always be added in the early stages of
the mixing process. It is recommended that Conplast MS be
weight batched to the required quantity prior to addition to the
mix.
In dry batching operations, Conplast MS should be dry
blended with aggregates and cement prior to the addition of
water to the mixer. In wet batching operations Conplast MS
should be added to the mixer at the same time as the cement.
Conplast MS can if required, be added to the mixer in slurry
form.
In order to achieve a low water cement ratio, the use of high
range water reducing admixtures such as Conplast SP430,
Conplast SP423 are highly recommended.
Placing
When producing concrete with Conplast MS we suggest a
target slump in the range of 25 to 35 mm in excess of the
normal slump requirement, this will accomodate the additional
cohesion promoted by the use of Conplast MS.
Concrete produced with Conplast MS will have greatly
improved cohesive qualities.
Estimating
Packaging
Conplast MS is available in 15 kg bags.
Storage
Conplast MS has a minimum shelf life of 12 months if stored
in a dry location in unopened packs
Conplast® MS
INDIA/2005/0121/D
Important note :
Fosroc products are guaranteed against defective materials and manufacture and are sold subject
to its standard terms and conditions of sale, copies of which may be obtained on request. Whilst
Fosroc endeavours to ensure that any advice, recommendation specification or information it may
give is accurate and correct, it cannot, because it has no direct or continuous control over where
or how its products are applied, accept any liability either directly or indirectly arising from the
use of its products whether or not in accordance with any advice, specification, recommendation
or information given by it.
telephone fax e-mail
++91 80-22240018/120 ++91 80-22233474 india@fosroc.com
Fosroc Chemicals (India) Pvt. Ltd.
Head Office
111/3, Hafeeza Chamber II Floor,
K H Road, PBNo. 2744, Bangalore 560027
www.fosroc.com
® Denotes the trademark of Fosroc International Limited
Regional Offices
Bangalore Mumbai Delhi Kolkata
Shankar House, IV Floor 208/209, Persepolis First floor,1/2 East Patel Nagar P-569, Lake Terrace Extn.
1 & 18, RMV Extension Sector 17, Vashi Opp: Vivek Cinema, Main Patel Rd First Floor
Bangalore 560 080 Navi Mumbai 400 703 New Delhi 110 008 Kolkata 700 029
Ph:080-2361 3161/2361 2004 Ph:022-2789 6412/14 Ph:011-25884903/4 Ph: 033 24650917 / 55343188
Fax : 080-2361 7454 Fax: 022 - 2789 6413 Fax: 011- 25884422 Fax: 033-24650891
email: Bangalore@fosroc.com email:Mumbai@fosroc.com email:Delhi@fosroc.com email:Kolkata@fosroc.com
z Ahmedabad : (079) 26762799 z Ankleshwar :(02646) 220704/224687 z Bhubaneshwar : (0674) 2546415 z Chennai (044) 24899949/24853383
z Chandigarh : (0172) 2639360 z Cochin : (0484) 2356668 z Coimbatore : (0422) 2472966 z Goa : (0832) 2542465 z Guwahati (0361) 2548793
z Hyderabad : (040) 27662324/27662425 z Hubli (0836) 09343402597 z Indore : (0731) 504339/5061477 z Jaipur : (0141) 2235349
z Jamshedpur: (0657) 2223848 z Lucknow :(0522) 2239044 z Nagercoil 09842134873 z Visakhapatnam : (0891) 2564850 / 2707607
Precautions
Health and Safety
Conplast MS is non-flammable. It may cause dust pollution
and irritation to respiratory tract. Hence wear suitable dust
mask, protective gloves and goggles while handling the
material. Incase of contact with eyes, rinse immediately with
plenty of water and seek medical advice. If swallowed, seek
medical attention immediately - do not induce vomitting.
Cleaning and disposal
The disposal of excess or waste material should be carried
out in accordance with local statutory requirements.
Additional Information
In addition to concrete admisture, Fosroc manufactures a
wide range of complementary products which includes
waterproofing membranes, joint sealants, grouts and anchors
and specialised flooring materials.
Additionally, a wide range of products specifically designed
for the repair and refurbishment of damaged reinforced
concrete is available.
This include hand-placed and spray-grade repair mortars,
fluid micro-concretes, chemical resistant epoxy mortars and
a comprehensive package of protective coatings.
For further information please contact your local Fosroc office
Nitobond EP Standard is a two component epoxy bonding agent sup-plied in pre-weighed quantities for ready on-site mixing and use.
1. Can be applied on concrete & mortar substrate
2. Facilitates improvement in mechanical strength
3. Good positive adhesion
4. Helps in bonding old and new cementitious substrates
5. Tools and equipment shall be cleaned thoroughly after use with Nitoflor Sol
1.Excellent durability - high compressive, flexural and tensile strengths ensure a long working life.
2. Cost effective - high early strength gain promotes minimum downtime and early commissioning of plant.
3. User friendly - simple, full pack mixing to ensure that the performance characteristics are achieved
4. Versatile - suitable for a wide range of loading situations including repetitive dynamic loads.
5. Excellent in service performance - non-shrink capability ensures full surface to surface contact
1, Provides good bond to concrete, masonry, stone work, plaster and block work
2. Improves tensile and flexural properties of mortar
3. Compatible with all common hydraulic cements
4. No bleeding and segregation
5. Nitobond AR Std. bonding aid has a shelf life of 12 months
FOSROC
product-detail-entry-exit
Mangalam Heights, Block No. c -8, 1st Floor, Model Mill Square, Ganeshpeth, - 440018, Maharashtra